The following recount criterion is for a pair of counts that estimate AC in fibers/cc. The criterion is given at the type-I error level. That is, there is 5% maximum risk that we will reject a pair of counts for the reason that one might be biased, when the large How To Remove Asbestos Siding observed difference is really due to chance. 

Reject a pair of counts if: Where: AC1 = lower estimated  airborne fiber concentration AC2 = higher estimated airborne fiber concentration ACavg = average of the two concentration estimates (FB) = for the average of the two   concentration estimates If a pair of counts are rejected by this criterion then, recount the rest of the filters in the How To Remove Asbestos Siding submitted set. 

Apply the test and reject any other pairs  failing the test. Rejection shall include a memo to the industrial hygienist stating that the sample failed a statistical How To Remove Asbestos Siding test for homogeneity and the true air concentration may be significantly different than the reported value. 7.4. Reporting Results Report results to the industrial hygienist as fibers/cc. 

Use two significant figures. If multiple analyses are performed on a How To Remove Asbestos Siding sample, an average of the results is to be reported unless any of the results can be rejected for cause. 8. References 8.1. Dreesen, W.C., et al, U.S. Public Health Service: A Study of Asbestosis in the Asbestos Textile Industry, (Public Health Bulletin No. 241), US Treasury Dept., Washington, DC, 1938. 8.2. 

Asbestos Research Council: The Measurement of Airborne Asbestos Dust by the Membrane Filter How To Remove Asbestos Siding Method (Technical Note). Asbestos Research Council, Rockdale, Lancashire, Great Britain, 1969. 8.3. Bayer, S.G., Zumwalde, R.D., Brown, T.A., 

Equipment and Procedure for Mounting Millipore Filters and Counting Asbestos Fibers by Phase Contrast Microscopy, Bureau of Occupational Health, U.S. Dept. of Health, How To Remove Asbestos Siding Education and Welfare, Cincinnati, OH, 1969. 8.4. NIOSH Manual of Analytical Methods, 2nd ed., Vol. 1 (DHEW/ NIOSH Pub. No. 77-157-A). 

National Institute for Occupational Safety and Health, Cincinnati, OH, 1977. pp. 239-1-239-21. 8.5. Asbestos, Code of Federal Regulations 29 CFR 1910.1001. 1971. 8.6. Occupational Exposure to Asbestos, Tremolite, Anthophyllite, and Actinolite. Final How To Remove Asbestos Siding Rule, Federal Register 51:119 (20 June 1986). pp. 22612-22790. 8.7. 

Asbestos, Tremolite, Anthophyllite, and Actinolite, Code  of Federal Regulations 1910.1001. 1988. pp 711-752. 8.8. How To Remove Asbestos Siding Criteria for a Recommended Standard -- Occupational Exposure to Asbestos (DHEW/NIOSH Pub. No. HSM 72-10267), National Institute for Occupational Safety and Health NIOSH, Cincinnati,OH. 

Leidel, N.A., Bayer,S.G., Zumwalde, R.D.,Busch, K.A., USPHS/NIOSH Membrane Filter How To Remove Asbestos Siding Method for Evaluating Airborne Asbestos Fibers (DHEW/NIOSH Pub. No. 79-127). National Institute for Occupational Safety and Health, Cincinnati, OH.

Applications of Optical Microscopy in Analysis of Asbestos and Quartz, Analytical How To Remove Asbestos Siding Techniques in Occupational Health Chemistry, edited by D.D. Dollberg and A.W. Verstuyft. Wash. D.C.: American Chemical Society, (ACS Symposium Series 120) 1980. pp. 13-41. 

Quality Control The OSHA asbestos regulations require each laboratory to establish a quality control program. The following is presented as an example of how the OSHA-SLTC constructed its internal curve as part of meeting this requirement. Data is from How To Remove Asbestos Siding samples collected during OSHA compliance inspections and analyzed from October 1980 through April 1986. 

Each sample was counted by 2 to 5 different counters independently of one another. The standard deviation and the statistic was calculated for each sample. This How To Remove Asbestos Siding data was then plotted on a graph of vs. fibers/mm(2). A least squares regression was performed using the following equation: where: Application of least squares gave: 

Using these values, the equation becomes: Sampling Pump Flow Rate Corrections This How To Remove Asbestos Siding correction is used if a difference greater than 5% in ambient temperature and/or pressure is noted between calibration and sampling sites and the pump does not compensate for the differences. 

(For Equation D, ) Where: Q(act) = actual flow rate Q(cal) = calibrated flow rate (if a rotameter was used, the rotameter value) P(cal) = uncorrected air pressure at calibration P(act) = uncorrected air pressure at sampling site T(act) = temperature at How To Remove Asbestos Siding sampling site (K) T(cal) = temperature at calibration 

Graticule When ordering the Graticule for asbestos counting, specify the exact disc diameter needed to fit the ocular of the microscope and the diameter (mm) of the circular counting area. Instructions for measuring the How To Remove Asbestos Siding dimensions necessary are listed: (1) 

Insert any available graticule into the focusing eyepiece and focus so that the graticule lines are sharp and clear. (2) Align the microscope. (3) Place a stage micrometer on the microscope How To Remove Asbestos Siding object stage and focus the microscope on the graduated lines. (4) Measure the magnified grid length, PL (um), using the stage micrometer. 

Remove the graticule from the microscope and measure its actual grid length, AL (mm).  This can be accomplished by using a mechanical stage fitted with verniers, or a jeweler's loupe with a direct reading scale. (6) Let D = 100 um. Calculate the  How To Remove Asbestos Sidingcircle diameter, d(c)(mm), for the Walton-Beckett graticule and specify the diameter when making a purchase.

Each eyepiece-objective-reticle combination on the microscope must be calibrated. Should any of the three be changed (by zoom adjustment, disassembly, replacement, etc.), the  How To Remove Asbestos Siding combination must be recalibrated. Calibration may change if interpupillary distance is changed. 

Measure the field diameter.acceptable range: 100 plus or minus 2 um) with a stage micrometer upon receipt of the graticule from the manufacturer. Determine the How To Remove Asbestos Siding field area. The Graticule is available from: Graticules Ltd., Morley Road, Tonbridge TN9 IRN, Kent, England (Telephone 011-44-732-359061). 

Also available from PTR Optics Ltd., 145 Newton Street, Waltham, MA 02154 [telephone (617) 891-6000] or McCrone Accessories and How To Remove Asbestos Siding Components, 2506 S. Michigan Ave., Chicago, IL 60616 [phone (312)-842-7100]. The graticule is custom made for each microscope. Counts for the Fibers in the Figure.

Clean Up Flood Damage And Hazardous Materials

In all likelihood, hazardous materials will be encountered during the cleanup phase of the flood recovery effort: containers and other vessels that may hold materials that can either pose an immediate risk to cleanup crews if disturbed or might be classified as a hazardous waste for disposal purpose  read more..

Tree Removal From Thunderstorms

The Inyo National Forest, Mammoth Ranger District is soliciting comments on a proposed project to remove wind-fallen trees from Reds Meadow Valley. On November 30 of last year an extreme wind event caused large numbers of trees to be blown down Wind Damage Tree Removal From Thunderstorms in the Reds Meadow Valley. 
<  read more..

Lead Testing In Soil

Is there lead in the soil outside your home? It may have gotten there from paint on the outside of the building or from industry. Or it may have come from car exhaust from the days when gasoline contained lead. Children can be poisoned if they play in soil that has lead in it or if someone trac  read more..

Federal Grants For Residential Flood Protection

Odds are that the area where you live will flood again. Before you spend a great deal of money and Flood Damage Federal Grants For Residential Flood Protection effort repairing and rebuilding, ask yourself this question:Do I really want to be flooded again?If you think that you would be better off in a different location,talk to your local government or   read more..

Facts About Asbestos Removal

Residents could have inhaled Libby asbestos fibers from household dust—either from plant emissions that infiltrated into homes or Asbestos Abatement Facts About Asbestos Removal from dust brought inside from waste products brought home for personal use. 

No information on past levels of contamina  read more..

File An Insurance Fire Damage Claim

You may be at an even greater risk of flooding due to recent fire that have burned across the region. Large-scale fire dramatically alter the terrain and ground conditions. Normally, Fire Damage File An Insurance Fire Damage Claim vegetation absorbs rainfall, reducing runoff. 

However, fire leave th  read more..

Lead Paint Exposure To Iron Workers

Field measurements using a tape measure of 12 of the cuts revealed that the paint was stripped back an average of 1.15 (range of 0.5 to 4.0 inches) inches from the cut line (based on 69 measurements taken). After hot cutting, Lead Paint Removal Lead Paint Exposure To Iron Workers burned paint provided visual evidence that stripping was insuffi  read more..

How To Write A Renter To Cleanup A Rental

Provide and maintain receptacles to remove trash, and pay for its frequent removal.-A lease for a single-family rental property may require a tenant to provide and maintain their own receptacles, and to pay for trash collection service if it is not located in a County collection district Tenant Move Out Cleanup How To Write A Renter To Cleanup A Rental&n  read more..

How To Test For Hoarding

Over the past year, my office has received an unusually high volume of calls from constituents who find themselves in difficult situations because of their out-of-control, overly cluttered apartments. Dismayed by the number of residents that are not only in danger of losing their homes, Hoarding How To Test For Hoarding&nb  read more..

Lead Testing

Prior to the 1970s, house paint often contained some lead. As lead house paint ages, it could chip or crumble into dust. Subject to lead-house paint dust or chips could cause serious Lead Paint Removal Lead Testing health issues. Little children and pregnant women are at higher threat. So, if you live in or own an older home,  read more..