Odor Control >> Problems With Plumbing Smells

Evaluation of Odors from Sewer Pipes On-Line TRS Analyzer An on-line TRS analyzer was installed at a manhole in each study site. The head space gas of each manhole was collected once every five min and was fed into the TRS analyzer. The TRS analyzer thermally oxidizes reduced sulfur compounds in a sample gas to SO2, Problems With Plumbing Smells which is subsequently quantified with an optical sensor [18].

Before each on-line TRS analyzer was installed, it was calibrated with standard H2S gas. In addition, Problems With Plumbing Smells the instrument was regularly maintained to ensure accurate measurements. The R2of the calibration curves was always higher than 0.9996 in the range 0 to 1,000 ppb (Figure 2). The TRS analyzers were operated for a week before and after the treatment at each site.

Example calibration curve for on-line TRS analyzer against standard H2S gas.In order to confirm the major odorous compounds from sewer systems, two or three gas samples were collected from the inside of a manhole located in each study sites, Problems With Plumbing Smells except District-FIVE, and were analyzed 1 to 2 months before the deodorant evaluation study was initiated. 

In fact, it was found that sulfur compounds were the major odorants. The TRS concentration measured by the TRS analyzer on-site and odor dilution of the samples collected from the sites showed a good linear correlation (Figure 3). Therefore, Problems With Plumbing Smells it was confirmed that the on-line TRS analyzer could be used as a tool to monitor the odor emissions from sewer systems and to evaluate the efficiency of any odor reducing technology.

Odor dilution vs. TRS concentration from the sewers in the study sites.2.3.2.Measurement of Odor and Individual Odorants In general, sampling and analysis of odorous gases were performed following the Korean Odor Measurement and Analysis Methods [19,20]. Brief explanations of the Problems With Plumbing Smells sample collection and analysis methods are provided below. 

Collection, Transportation and Storage of Samples The gas samples were taken from the monitoring site of each district (e.g., from a street inlet or a manhole located on 300to500 m downstream from the agent-spraying point) at three different times before and after the Problems With Plumbing Smells treatment. The gas samples were collected for 5 min with a diaphragm pump regulated by a flow meter and operating at 4 L·min−1using a 20 L Tedlar bag. 

Tedlar bags were cleaned three times with high purity nitrogen before use and the pump and the tubes were also cleaned by flowing high purity nitrogen through them for 3 min. After collection, samples were stored in light resistant containers, Problems With Plumbing Smells and were sent to a third party operating a certified laboratory for determining odor dilution, and to our laboratory for instrumental analysis of individual odorants. 

All the samples were analyzed within a day after collection.Determination of Odor DilutionOdors of collected gas samples were determined by a third party panel. The Problems With Plumbing Smells samples for the panel evaluation were mixed with odor-free air with the dilution factor of 3, 10, and 30 times and so on using an auto-dilution unit. The odor panel was composed of five males over 19 years old. 

All of them had passed a screening test specially designed for panel candidates. Analysis of Individual Odorants A set of gas samples were collected Problems With Plumbing Smells and analyzed for individual odorants (i.e., NH3, H2S, CH3SH, DMS, and DMDS) following the Korean Odor Measurement and Analysis Methods [19]. 

For NH3analysis, the gas in the headspace of each sewer was absorbed by an acid solution in a bottle; the gas was passed through the acid solution at 10 L·min−1for 5 min. The concentration of the absorbed NH3was quantified following the Problems With Plumbing Smells standard methods. Sulfur compounds (i.e., CH3SH, H2S, DMS, and DMDS) in a gas sample collected by a Tedlar bag were analyzed by a cold concentrated-capillary column GC-FPD method. 

In addition, the effect of odor reducing agents on the water quality of the wastewater in the sewer at each site was also evaluated by collecting water samples before and after the treatment at each site, Problems With Plumbing Smells and by measuring water temperature, pH, BOD, SS, and NH3. Go to:3. Results and Discussion Effectiveness of Agent-A in Control of Odors from Sewer

Figure 4(A) shows the TRS profiles monitored by the on-line TRS analyzer before (A1) and after (A2) Agent-A was applied at District-ONE.Time profiles of TRS measured at Districts-ONE to FOUR before and after application of Agents-(A to D). Since a few governmental office buildings are located in the area along with many restaurants Problems With Plumbing Smells and coffee shops, large amounts of wastewater are intermittently discharged from the noon to evening. 

The wastewater discharge is also identified by the on-line TRS analyzer. From Figure 4(A), intermittent releases of large amount of sulfur compounds were observed; especially the peaks often appeared from lunch time to the evening. On the other hand, Problems With Plumbing Smells low concentrations of TRS were detected from dawn till noon. 

The times when the TRS peaks were observed were identical to the pumping times for outflows from the septic tanks in the large buildings along the street,  Problems With Plumbing Smells indicating that the odor emission from the sewer was mainly due to the activity of the commercial areas. It was found that there was little difference between the TRS profiles before and after the treatment were compared. 

The daily average TRS concentrations of the site before and after the Agent-A was applied were almost the same;i.e., 370 ppb and 410 ppb for before and after the treatment, Problems With Plumbing Smells respectively. At the study site of the District-ONE, the gas samples were collected before and after the agent applied, and analyzed both for odor and individual odorants. 

The samples were collected during the day times (13:00 to 15:00). The odorous gas samples were collected three times at intervals of 20 to 40 min. In general, Problems With Plumbing Smells there was not a statistically significant difference in the odor dilutions obtained from the panel evaluation for the gas samples collected before and after the application of the Agent-A (p= 0.91). 

Although gas samples for measuring odor dilution were collected when two odor panels were noticed odor emission, still large deviations could be observed from the study (Table 2). However, Problems With Plumbing Smells it should be noted that olfactory measurement can produce large deviations, especially at lower odor dilutions [11].

How To Abate Remove Lead

The employer shall maintain the record of the objective data relied upon for at least 30 years. (5) Availability. The employer shall make available upon request all records required to be maintained by subsection (n) to affected employees,former employees, and their designated representatives, and t  read more..

Structural Drying

If you have Mold Remediation Structural Drying in your office, in your home or maybe even in your car or your boat. You will first need to clean these areas thoroughly to remove any surface mold. Mold is a fungus that is reproduced by putting out spores that are lighter than air they will land and then begin to multiply.   read more..

Surviving A Tornado

Risk Assessment: Wind/Tornadoes Description The term "straight-line winds" is used to distinguish common, non-rotating winds from tornado-related winds. Straight-line winds are responsible for most thunderstorm wind damage, Wind Damage Surviving A Tornado with wind speeds in excess of 100 miles per hour on occasion.  read more..

Animal Control How To Get Rid Of Squirrels In The

Evaluate animal damage management needs and conduct predator control in cooperation with the Forest Service, state agencies, and permittees. Serve as lead agency for preparing Animal Damage Animal Control How To Get Rid Of Squirrels In The environmental documentation on animal damage management activities initiated by APHIS on National Forest System lands.   read more..

Dehumidification

One place definitely going to see Mold Remediation Dehumidification is in the bathroom. The main culprit in this area is going to be believe it or not behind the tile in your shower. Because showers that have tile walls are usually placed over drywall, and have porous grout joints. The drywall behind is usually not as we  read more..

Facts About Asbestos Removal

Residents could have inhaled Libby asbestos fibers from household dust—either from plant emissions that infiltrated into homes or Asbestos Abatement Facts About Asbestos Removal from dust brought inside from waste products brought home for personal use. 

No information on past levels of contamina  read more..

Raw Sewage Is Extremely Hazardous

This document has been jointly prepared by the Massachusetts Department of Public Health Division of Community Sanitation (DPH), and the Massachusetts Department of Environmental Protection (MassDEP) and is intended to provide guidance to the general public relative to managing pathogen risks from d  read more..

Flood Protection Methods

Illinois can flood in any season. Floods have been caused by localized storms, rain over severaldays on saturated ground, snow melt, and ice jams. Over the last two decades, Flood Damage Flood Protection Methods a significant floodhas occurred somewhere in the state each year.

Many of them received a state or federa  read more..

Lead Paint In All Construction Work

This section applies to all construction work where an employee may be occupationally exposed to lead. All construction work excluded from coverage in the general industry standard for lead by section 5216(a)(2) is covered by this standard. Construction work is defined as work for construction, alte  read more..

DIY Removing Smoke Damage From Wood

In one set of tests, the vertical plates were placed with a fixed spacing of 2.5 mm. In these tests, the plates were biased with 5 Vdc, 50 Vdc, 500 Vdc and 1 Vac. The current flow between the dc-biased plates was monitored during exposure. The ac-biased plates were analyzed to measure Smoke Damage DIY Removing Smoke Damage From Wood   read more..