Radon Mitigation >> Radon Element

Note: If you are a former smoker, your risk may be higher. Lifetime risk of lung cancer deaths from EPA Assessment of Risks from Radon Element in Homes (EPA 402-R-03-003). Comparison data calculated using the Centers for Disease Control and Prevention's 1999-2001 National Center for Injury Prevention and Control Reports. 

The Solution Why Should Every Home be Tested? The EPA and the U. S. Surgeon General recommend testing all homes below the Radon Element third floor for radon. Data gathered by the EPA national radon survey indicate that elevated radon levels are present in about six million (6,000,000) homes throughout the United States. 

In every state there are homes with dangerously high Radon Element levels. Because the radon concentration inside a home is due to factors relating to its structure and geographic location, each individual home must be tested to determine its radon level. Two adjacent houses may have radically different radon levels. 

And any kind of home can have elevated levels -- new or old, drafty or well-sealed, and basement or non-basement. How do You Obtain a Reliable Test Result? Although radon cannot be seen or smelled, with the proper equipment its presence is relatively easy to detect. The EPA operated a voluntary National Radon Element Proficiency (RPP) Program that evaluated radon measurement companies and the test services they offer until 1998. 

You can find out how to find a "qualified" radon Service Professional in your area - www.epa.gov/radon/radontest.html. radon Testing Methods The quickest way to test for radon is with a short-term "do-it-yourself" radon test kit, available by mail order and Radon Element in many retail outlets or by hiring an EPA qualified or state-certified radon tester. 

Common short-term test devices are charcoal canisters, alpha track detectors, liquid scintillation detectors, electret ion chambers, and continuous monitors. A short-term testing device remains in the home for two (2) to ninety (90) days, depending on the type of device. Because radon levels tend to vary from day-to-day and season-to-season, a long-term test is more likely than a short-term test to measure the home's year-round average Radon Element level. 

If results are needed quickly, however, Radon Element a short-term test followed by a second short-term test may be used to determine the severity of the radon problem. Long-term test devices, comparable in cost to devices for short-term testing, remain in the home for more than three (3) months. A long-term test is more likely to indicate the home's year-round average radon level than a short-term test. 

Alpha track detectors and electret ion detectors are the most common long-term test devices. radon Test Devices Charcoal canister and liquid scintillation detectors contain small quantities of activated charcoal. radon and its decay products are absorbed onto the charcoal and Radon Element are measured by counting with a sodium iodide detector or a liquid scintillation counter. 

Alpha track detectors contain a small sheet of plastic that is exposed for a period of one (1) to three (3) months. Alpha particles etch the plastic as they strike it. These marks are then chemically treated Radon Element and counted in the laboratory to determine the radon concentration. Electret ion detectors contain an electro statically charged Teflon disk. 

Ions generated by the decay of radon strike and reduce the surface voltage of the disk. By measuring the voltage reduction, the radon concentration can be calculated. Continuous monitors are active devices which need power to function. They require operation by trained testers and work by continuously measuring Radon Element and recording the amount of radon in the home. 

How To Test During a short-term test, doors and windows are closed twelve (12) hours prior to testing and Radon Element throughout the testing period. (A short-term test lasting two (2) or three (3) days should not be conducted during unusually severe storms or periods of unusually high winds.) 

The test kit is placed in the lowest lived-in level of the home, at least twenty (20) inches above the floor, Radon Element in a room that is used regularly, but not in the kitchen or bathroom where high humidity or the operation of an exhaust fan could affect the validity of the test. 

At the end of the test period, the kit is mailed to a laboratory for analysis; results are mailed back in a few weeks. In some cases, Radon Element such as real estate transactions, "qualified" or state-certified contractors conduct the radon test. The EPA's guidance Home Buyer's and Seller's Guide to radon addresses issues during real estate transactions. 

Interpreting radon Test Results 1. If the short-term test result is 4 pCi/L or higher, Radon Element conduct a follow-up test to confirm the results. 2. Follow-up with either a long-term test or a second short-term test. For a better understanding of the home's year-round average radon level, take a long-term test. If results are needed quickly, take a second short-term test. 

The higher the initial short-term result, Radon Element the more certain the homeowner can be to conduct a short-term rather than a long-term follow-up test. If the first short-term test result is several times the action level - for example, about 10 pCi/L or higher - a second short-term test should be taken immediately. 3. If the long-term follow-up test result is 4 pCi/L or more, fix the home. 

If the homeowner followed up with a second short-term test: the higher the short-term results, Radon Element the more certain the homeowner can be that the home should be fixed. The homeowner should consider fixing the home if the average of the first and second test is 4 pCi/L or higher.

Guidelines For Mold Abatement Contractors

A variety of organic dust sources may cause HP. The causative agents may include bacteria, fungi, animal proteins, insects, and chemicals. The numerous clinical syndromes are generally given names reflecting the circumstances or sources of exposure. For example, farmer's lung results from exposures   read more..

The Effects Meth Labs Have On Wildlife And Vegetat

In addition to the General Cleanup Requirements in Section B, at aminimum a typical cleanup for a Tier 2 Response shall Meth Lab Cleanup The Effects Meth Labs Have On Wildlife And Vegetat include the following:1) Where applicable/appropriate, follow all cleaning procedures described in Tier 1.2) This Tier differs from Tier 1 Responses in that additional af  read more..

How To Remove Asbestos From A Roof

Asbestos Requirements for Demolition and Renovation Projects 6/2013 Disclaimer: The statements in this Asbestos Abatement How To Remove Asbestos From A Roof document are intended solely as guidance. This document is not intended, nor can it be relied on, to create any rights enforceable by any party in litigation.  

  read more..

Crime And Trauma Scene Biorecovery Training

Regulated waste must be disposed of according to federal, state, and local regulations. Place all regulated waste in closable and biohazard labeled or color-coded containers (bags). Waste, may be placed in plastic,  Crime Scene Cleanup Crime And Trauma Scene Biorecovery Training sealable bags before disposal in a larger biohazard bag in order to reduce  read more..

Hurricane Katrina Flooding

FLOODED SEPTIC SYSTEMS What should I do if my septic system was flooded or damaged? Don’t use the system if the soil around the system is wet and flooded. The waste water will not be treated and will become a source of pollution.Once floodwaters have receded, Water Damage Hurricane Katrina Flooding there are several things  read more..

Companies That Clean Repos

In whom is vested all or part of the legal title to property or all or part of the beneficial ownership of property and a right to present use of the premises; the term includes a mortgagee in possession; (15) "premises" means a dwelling unit and the structure of which it is a part and facilities an  read more..

Radon Transform

RADON TRANSFORM MITIGATION STANDARDS 1.0 BACKGROUND The 1988 Indoor Radon transform Abatement Act (IRAA) required the Environmental Protection Agency (EPA) to develop a voluntary program to evaluate and provide information on contractors who offer radon transform Radon Mitigation Radon Transform control services to h  read more..

Pipe Leaks

Water Damage Pipe Leaks could be called the silent destroyer, there might be a water leak for days that goes unnoticed then squish you step into it with your stocking feet. But, you think, where did it come from, it’s fairly close to the kitchen sink. You open the cabinet and pull everything out from insid  read more..

How To Choose A Professional Dehumidifier

Flat-plate heat exchangers consist of a series of flat Dehumidification How To Choose A Professional Dehumidifier or nearly flat heat exchange surfaces arranged in such a way that alternating air passages are connected to one air stream with remaining passages connected to the second air stream. the recuperative application of the air-to-air   read more..

Radon Gas

What is Radon gas? Radon gas is a gas produced by the radioactive decay of the element radium. Radioactive decay is a natural, spontaneous process in which an atom of one element decays or breaks down to form another element by losing atomic particles (protons, neutrons, or electrons). When solid ra  read more..